[MSL-4]

Acoustical (each loudspeaker) Operating Frequency Range (1)
}4 dB from 65 Hz to 18 kHz
@
-6 dB at 60 Hz and 20 kHz
Phase Response (1)
}30 from 450 Hz to 10 kHz
Maximum SPL (1)
140 dB @ 1 meter
Dynamic Range
> 110 dB
Coverage
40 Horizontal x 35 vertical
Crossover
800 Hz
Transducers   Low Frequency
12" Cone driver
High Frequency
2" Throat, 4" diaphragm compression driver
Audio Input Type
10 k ohm impedance, electronically balanced
Connector
Female XLR input and male XLR loop output or VEAM
Nominal Input Level
+4 dBu
Amplifiers  Type
Complementary power MOSFET output stages (audio class AB/H)
Burst Capability (2)
1240 Watts (620 watts/channel)
THD, IM, TIM
< .02 %
 AC Power Connector
250V NEMA L6-20 (Twistlock) inlet, IEC 309 male inlet or VEAM(3)
Automatic Voltage Selection
85 - 134 VAC; 165 - 264 VAC; 50/60 Hz (4)
Operational Voltage Range
Turn on: 85 VAC; Turn off: 134 VAC; 50/60 Hz
@
Turn on: 165 VAC; Turn off: 264 VAC; 50/60 Hz
Max.Continuous RMS Current (> 10 sec)
at 115 V: 8 A rms
at 230 V: 4 A rms
at 100 V: 10 A rms
Burst RMS Current (< 1 sec)
at 115 V: 15 A rms
at 230 V: 8 A rms
at 100 V: 18 A rms
Max Peak Current During Burst
at 115 V: 22 A pk
at 230 V: 11 A pk
at 100 V: 25 A pk
Inrush current
< 12 A at 115 V
Notes 1. Subject to half-space loading, measured with one-third octave frequency resolution in fixed ISO bands.
2. Nominal 8 ohm resistive load, pink noise, 100 V peak.
3. Other connectors available. For European applications, the IEC 309 (16A) panel is used.
4. The unit is rated at 88-125 V and 182-235 V, 50/60 Hz, to satisfy EC standards for -10% to 6% AC line voltage.