[MSL-4]
Acoustical (each loudspeaker) Operating Frequency Range (1)
|
}4 dB from 65 Hz to 18 kHz |
@
|
-6 dB at 60 Hz and 20 kHz |
Phase Response (1)
|
}30 from 450 Hz to 10 kHz |
Maximum SPL (1)
|
140 dB @ 1 meter |
Dynamic Range
|
> 110 dB |
Coverage
|
40 Horizontal x 35 vertical |
Crossover
|
800 Hz |
Transducers Low Frequency
|
12" Cone driver |
High Frequency
|
2" Throat, 4" diaphragm compression driver |
Audio Input Type
|
10 k ohm impedance, electronically balanced |
Connector
|
Female XLR input and male XLR loop output or VEAM |
Nominal Input Level
|
+4 dBu |
Amplifiers Type
|
Complementary power MOSFET output stages (audio class AB/H) |
Burst Capability (2)
|
1240 Watts (620 watts/channel) |
THD, IM, TIM
|
< .02 % |
AC Power Connector
|
250V NEMA L6-20 (Twistlock) inlet, IEC 309 male inlet or VEAM(3) |
Automatic Voltage Selection
|
85 - 134 VAC; 165 - 264 VAC; 50/60 Hz (4) |
Operational Voltage Range
|
Turn on: 85 VAC; Turn off: 134 VAC; 50/60 Hz |
@
|
Turn on: 165 VAC; Turn off: 264 VAC; 50/60 Hz |
Max.Continuous RMS Current (> 10 sec)
|
at 115 V: 8 A rms at 230 V: 4 A rms at 100 V: 10 A rms |
Burst RMS Current (< 1 sec)
|
at 115 V: 15 A rms at 230 V: 8 A rms at 100 V: 18 A rms |
Max Peak Current During Burst
|
at 115 V: 22 A pk at 230 V: 11 A pk at 100 V: 25 A pk |
Inrush current
|
< 12 A at 115 V |
Notes | 1. Subject to half-space loading, measured with
one-third octave frequency resolution in fixed ISO bands. 2. Nominal 8 ohm resistive load, pink noise, 100 V peak. 3. Other connectors available. For European applications, the IEC 309 (16A) panel is used. 4. The unit is rated at 88-125 V and 182-235 V, 50/60 Hz, to satisfy EC standards for -10% to 6% AC line voltage. |